These case studies represent the types of projects Fire Stopper Systems completes across the U.S. commercial and industrial market. Each one illustrates the specific challenge that tube suppression solves — and why alternative systems were not viable.
The facility’s existing overhead clean agent system provided room-level protection but left individual rack enclosures unprotected at the component level. The insurance carrier’s new requirements mandated rack-level suppression documentation. Previous suppression contractors quoted conventional sensor-based systems — which would have required power feeds to each rack and significant electrical work.
Fire Stopper Systems proposed a direct tube system mounted inside each high-density rack. No electrical connection to any rack. No sensor wiring. No control panel integration. Each tube was self-contained and independently documented. The 120-rack installation was completed by a two-person certified installer team in four working days.
The insurance carrier accepted the UL listing and FM Approval documentation and approved the insurance rider for the facility. The client reported a 12% reduction in their commercial property insurance premium, attributable in part to the documented rack-level suppression system. The facility’s compliance officer described the installation documentation as the most complete they had received from any fire suppression vendor.
The facility had experienced three arc flash events inside motor control center enclosures over a 24-month period. Each event caused MCC damage requiring shutdown, repair, and lost production time. The facility’s safety team identified the root cause as the absence of any suppression system capable of operating inside the MCC cabinet during a power fault. Standard sensor-based systems were considered but rejected because the arc flash events themselves killed power to the suppression control panel before activation could occur.
An indirect tube system was specified for each of the six MCCs across the facility. The heat-trigger tube was mounted inside each MCC cabinet. An external agent cylinder was connected via pressure valve. When internal temperature exceeds threshold, the tube triggers the cylinder — regardless of power status. Installation was phased to minimize production downtime, completing one MCC at a time during scheduled maintenance windows.
Zero enclosure fires in the 18 months following installation. The facility’s safety director reported that the elimination of arc flash fire risk inside MCC enclosures was a significant factor in their OSHA 300 log improvement for the period. Estimated avoided MCC replacement cost over the same 18-month period: approximately $1.2 million.
End customers — primarily automotive and aerospace manufacturers — were increasingly requiring certified fire suppression inside machine enclosures as a purchase condition. The OEM had no in-house solution and was losing competitive bids to European machine builders who offered factory-integrated suppression. Retrofitting machines in the field was expensive and logistically difficult.
Fire Stopper Systems worked with the OEM’s engineering team to design a tube routing configuration that fit within the machine cabinet’s existing interior geometry without interfering with electrical components or maintenance access. The direct tube system was integrated into the factory production line. Each unit shipped with UL listing documentation specific to the machine model.
Three major manufacturing customers cited the factory-integrated fire suppression system as a deciding factor in their purchasing decision within the first six months of availability. The OEM’s sales team reports the certification documentation has eliminated fire suppression as a procurement objection in new customer discussions.
Have a project with similar risks or constraints? We’ll help you identify the right suppression approach quickly.